| Sign In | Join Free | My futurenowinc.com | 
 | 
Brand Name : SONTUNE
Model Number : STN2
Certification : CE
Place of Origin : China
MOQ : 1-50pcs
Price : Negotiable
Supply Ability : 5000pcs/day
Standard : IEC 60947-2,GB14048.2
Coil voltage : AC400( 380 ),AC690( 660 ),DC500
In : 63,80,100,125,160,200,250,350A,400,500,630,800,1000,1200,1250,1600A
Type : MCCB
Install : Fixed
Color : Gray
Stn2 3p Moulded Case Circuit Breaker
Ambient air temperature
The ambient air temperature is about +40 ºC; the ambient air temperature is below -5ºC; the average value of ambient air temperature 24h is not more than +35ºC.
Elevation: installation elevation of not more than 2000m.
 
Atmospheric condition:
Relative humidity of the atmosphere in the surrounding air temperature of +40ºC is less than 50%; the relative humidity at the lower temperature can be high; most of the wet month average maximum relative humidity of 90%, the monthly average minimum temperature of +25ºC and considering the temperature due to changes in product surface.
Pollution grade: grade 3.
| Rated current of release(A) | Thermodynamic release (ambient temp +40°C) | operational current of magnetic ralease(A) | |||
| 1.05In(cold state) in operative time(h) | 1.30(heat state) inoperative time(h) | ||||
| In≤63 | ≥1 | <1 | 10In±20% | ||
| 63 | ≥2 | <2 | 10In±20% | ||
| 100 | ≥3 | <3 | 5-10In±20% | ||
| Rated current of release(A) | Thermodynamic release (ambient temp +40°C) | operational current of magnetic ralease(A) | |||
| 1.0 In(cold state) operative time(h) | 1.20(heat state) operative time(h) | 1.50(heat state) operative time(h) | 1.01(heat state) operative time(h) | ||
| 12.5 | ≥2 | <2 | ≤4min | 2s | 12In±20% | 
Note:
1. The N-pole breaker has no protection which closing and opening with the other three poles. 2. The type of thermal magnetic for NS-400/630 has no four poles.
1. Overload protection with adjustable threshold, as defined by IEC60947-4 (2) tripping class 10A,10 and 20
2. Short-circuit protection with adjustable threshold (6...13xIr)
3. Phase failure protection (built-in electronic release: operates unbalanced single-phase currentat 40% and more than )(tripping time delay 4s±10%),as defined by IEC60947-4.1
4. Load indication : Flashing more than Ir setting threshold
5. Fault indication
LEDs indicates the type of fault that caused tripping
Overload (LT protection) or abnormal component temperature (>Ir);
Short-circuit (ST or instantaneous protection)( >Im);
Phase failure (right LED);
Microprocessor malfunction ( (>Ir) ( >Im) and phase failure LEDs all go on )
Battery powered. Spare battery are supplied in an adapter box. When a fault occurs ,the LEDindicating the type of fault ,lights for about 10 minutes . The information is however stored inmemory . The LED can be illuminated by pressing the test pushbutton. The LED automatically goes off and the memory is cleared when the circuit breaker is reset .
 
Our Services:
|   | 
| Gray Fixed AC690 Square D Circuit Breakers GB14048 Standard With LED Images | 
 3P 4P Thermal Magnetic Molded Case Circuit Breaker With Overload Protection
                                                                                    
                        
                        
                        
                                                            3P 4P Thermal Magnetic Molded Case Circuit Breaker With Overload Protection
                                                    
                        
                     8kA Three and Four Pole Mould Case MCCB Circuit Breaker CE Passed Mini Circuit
                                                                                    
                        
                        
                        
                                                            8kA Three and Four Pole Mould Case MCCB Circuit Breaker CE Passed Mini Circuit
                                                    
                        
                     65kA 4 Pole Reliable Mccb Molded Case Circuit Breaker For High Power Application
                                                                                    
                        
                        
                        
                                                            65kA 4 Pole Reliable Mccb Molded Case Circuit Breaker For High Power Application
                                                    
                        
                     CE Certified 3P 100A MCCB Circuit Breaker , Mccb Switch With Normal Structure
                                                                                    
                        
                        
                        
                                                            CE Certified 3P 100A MCCB Circuit Breaker , Mccb Switch With Normal Structure
                                                    
                        
                     STM Moulded Case MCCB Circuit Breaker , Small High Voltage Protection ,25~100kA
                                                                                    
                        
                        
                        
                                                            STM Moulded Case MCCB Circuit Breaker , Small High Voltage Protection ,25~100kA
                                                    
                        
                     High Breaking Capacity MCCB Circuit Breaker 3P / 4P AC 400V Coil Voltage
                                                                                    
                        
                        
                        
                                                            High Breaking Capacity MCCB Circuit Breaker 3P / 4P AC 400V Coil Voltage
                                                    
                        
                     STS 3 Automotive Module Case Circuit Breaker AC 50HZ Overload Protection
                                                                                    
                        
                        
                        
                                                            STS 3 Automotive Module Case Circuit Breaker AC 50HZ Overload Protection
                                                    
                        
                     8~65kA 4 Pole MCCB Circuit Breaker Reliable Performance High Breaking Capacity
                                                                                    
                        
                        
                        
                                                            8~65kA 4 Pole MCCB Circuit Breaker Reliable Performance High Breaking Capacity
                                                    
                        
                     Ecnomic type STEZC Series Moulded case MCCB Circuit Breaker 100A to 630A with
                                                                                    
                        
                        
                        
                                                            Ecnomic type STEZC Series Moulded case MCCB Circuit Breaker 100A to 630A with
                                                    
                        
                     Moulded Case Adjustable Current MCCB Circuit Breaker 250A
                                                                                        
                                                        
                        
                        
                        
                                                            Moulded Case Adjustable Current MCCB Circuit Breaker 250A